Ningbo Hicon Industry Co., Ltd.
Ningbo Hicon Industry Co., Ltd.
Produk
Air Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger
  • Air Cooled Heat ExchangerAir Cooled Heat Exchanger

Air Cooled Heat Exchanger

Adhedhasar prinsip cooling evaporative, Hisurp majeng Air Cooled Heat Exchanger kanthi cepet cools online nang griya ijo kanthi nresep panas liwat penguapan banyu, nalika uga nyediakake ventilasi lan humidification. Iki minangka salah sawijining piranti inti kanggo ngontrol lingkungan omah kaca ing mangsa panas.

Aplikasi

Air Cooled Heat Exchanger, digawe ing China, dening Hisurp, bisa nyedhiyakake kontrol suhu lan sirkulasi udara sing luwih maju ing kebon kembang, omah kaca, tanduran nursery sayur-sayuran, peternakan lan akuakultur, bengkel lan pabrik.

Application
Application

Fitur

Anti-corrosion

Anti karat

Penggemar mbenakake piring lan pan banyu digawe saka sheet galvanis karo perawatan uyuh plastik, kang ayu lan anti korosif

Highly effective

Highly efektif

Proses exchanger panas cukup dirancang, nganggo tabung tembaga lan sirip aluminium corrugated hidrofilik struktur, tabung munggah mechanical, efficiency exchange panas dhuwur

Spesifikasi

Model Volume Udara
(m3/jam)
Kapasitas adhem
(kW)
Kapasitas Pemanasan
(kW)
Daya Motor
(W)
L*W*H
(mm)
WaterInlet lan OutletPipe Pipa Kondensat
FLHRQ420 2400 10.3 10.3 240 732*405*687 DN20 DN25

Cathetan:

1.adhem: suhu inlet lan outlet banyu sing adhem yaiku 7/12 ℃, suhu bohlam garing inlet yaiku 27 ℃, kelembapan relatif 60%, suhu bohlam garing udhara outlet yaiku 17 ℃, kelembapan relatif 90%;
2.Pemanasan: suhu inlet lan outlet banyu panas 50/40 ℃, suhu bohlam garing inlet 20 ℃, kelembapan relatif 50%, suhu bohlam garing udhara outlet 31,5 ℃
3.sumber daya: 3-380V 60Hz

Pancegahan Instalasi

(1) Air Cooled Heat Exchanger kudu diinstal dening profesional sing kenal karo produk sing padha lan ngerti peraturan lokal sing relevan;
(2) Sawise Air Cooled Heat Exchanger ing posisi, iku kudu tetep aman lan kudu katahan tingkat;
(3) Nalika nyambungake pipa inlet lan outlet, disaranake nggunakake pipa cadangan kanthi torsi ora luwih saka 205.6Nm kanggo nyegah twisting lan bocor;
(4) Sadurunge kabel, priksa manawa voltase, frekuensi lan jumlah fase sumber daya cocog karo syarat unit, lan panyimpangan voltase sumber daya ora luwih saka 10% saka voltase sing dirating. Penyimpangan voltase saka sumber daya ngirim ora ngluwihi 10% saka voltase dirating;